Home / All / Electrical equipment / Accessories for switchgear /

JN22B-40.5/31.5 Indoor high voltage AC grounding switch earthing switch from JUCRO Electric

JN22B-40.5/31.5 Indoor high voltage AC grounding switch earthing switch from JUCRO Electric

JN22B-40.5/31.5 Indoor high voltage  AC grounding switch earthing switch  from JUCRO Electric
JN22B-40.5/31.5 Indoor high voltage  AC grounding switch earthing switch  from JUCRO ElectricJN22B-40.5/31.5 Indoor high voltage  AC grounding switch earthing switch  from JUCRO Electric
CategoriesAccessories for switchgear
BrandJUCRO
ModelJN22B-40.5/31.5
Update TimeDec 11,2024
Detail Information
JN22B-40.5/31.5 Indoor high voltage  three-phase AC grounding switch earthing switch  from JUCRO Electric
GENERAL

JN22B-40.5/31.5 indoor high voltage grounding switch (hereinafter referred to as grounding switch) is a new product developed by the company. Its performance meets the requirements of national standard GB1985-2004 "AC high-voltage isolating switch and grounding switch" and IEC62271-102:2002. It is applicable to three-phase rated voltage 40.5kV, AC 50Hz power system, and KYN61-40.5 high voltage switch. Cabinets and other high-voltage switchgears are used together as a grounding protection for high-voltage electrical equipment maintenance.

The JN22B-40.5/31.5 indoor high voltage grounding switch is improved on the basis of the above grounding switch. The structure is simple and compact, the performance is consistent, and it is easy to operate at a small angle. As with the JN15-12 series, JN15-12 connections and transmissions are available.

WORKING CONDITION

1. The altitude does not exceed 1000m:

2. Ambient air temperature: +40°C ~ -20°C;

3. The earthquake intensity does not exceed 8 degrees;

4. Installed in a place where there is no fire, explosion hazard, severe dust, chemical corrosion and severe vibration.

CODING RULES

MAIN TECHNICAL PARAMETERS
Item
Unit
Data
Rated voltage
KV
40.5
Rated short-time withstand current
KA
31.5
Rated withstand current(peak value)
KA
80
Rated short-circuit making current
KA
80
Rated insulation level
Power frequency withstand voltage(1 min)
KV
95
Lightning impulse voltage
KV
185
 DIMENSIONS
Model
Phase to phase distance A
F
principal axis L
The height of the sensor for plateau type H
JN22B-40.5/31.5-280
280
290
1010

Below 1000 meters 145

Below 2000 meters 170

Below 3000 meters 185

Below 3000 meters 210
JN22B-40.5/31.5-300
300
340
1100
JN22B-40.5/31.5-350
350
340
1200
JN22B-40.5/31.5-360
360
320
1200
JN22B-40.5/31.5-400
400
340
1300
OVERALL AND INSTALLATION DIMENSIONS
Please send your message to us
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.

Professional production line solution provider!

MOBILE WEB
NEWSLETTER

Sign up today for hints, tips and the latest product news - plus exclusive special offers.

Tel:+0086-18131539058

subscription

We don’t do spam and Your mail id is very confidential.