Home / All / Electrical equipment / VCB Vacuum Circuit Breaker /

Vacuum Circuit Breaker HVD7 40.5KV 2000A outdoor HV AC VCB from Hubei JUCRO Electric

Vacuum Circuit Breaker HVD7 40.5KV 2000A outdoor HV AC VCB from Hubei JUCRO Electric

Vacuum Circuit Breaker HVD7 40.5KV 2000A outdoor HV AC VCB from Hubei JUCRO Electric
Vacuum Circuit Breaker HVD7 40.5KV 2000A outdoor HV AC VCB from Hubei JUCRO ElectricVacuum Circuit Breaker HVD7 40.5KV 2000A outdoor HV AC VCB from Hubei JUCRO ElectricVacuum Circuit Breaker HVD7 40.5KV 2000A outdoor HV AC VCB from Hubei JUCRO ElectricVacuum Circuit Breaker HVD7 40.5KV 2000A outdoor HV AC VCB from Hubei JUCRO ElectricVacuum Circuit Breaker HVD7 40.5KV 2000A outdoor HV AC VCB from Hubei JUCRO Electric
CategoriesVCB Vacuum Circuit Breaker
BrandJUCRO
ModelHVD7-40.5/2000
Unit PriceUS $ 7076-7674 / piece
Terms of PaymentL/C, Western Union, MoneyGram, T/T
Update TimeDec 11,2024
Detail Information

Vacuum Circuit Breaker HVD7 40.5KV 2000A outdoor HV AC VCB from Hubei JUCRO Electric

Vacuum Circuit Breaker accept customized order according to technical drawing or samples.

1. Introduction

HVD7 40.5KV 2000A outdoor HV AC vacuum circuit breaker VCB has many visual advantages like reasonable design, fashionable appearance, high safety and reliability, simple maintenance, long electric life. It is the ideal upgraded products of 35KV outdoor oil circuit breakers.

HVD7 40.5 2000A vacuum circuit breaker is applicable for three-phase power system of AC 50HZ.It is used to make and break the load current ,overload current and short-circuit current.

2. Applicable environment

2.1The ambient temperature should be -30degree~ +40degree(-40degree in the frosty area);

2.2Altitude should not exceed 2000m(over 2000m is plateau type); 

2.3The wind pressure should not exceed 700Pa(equal to wind speed 34m/s);

2.4Air pollution degree: 3,that of antifouling type:4;

2.5The installation site should be free from the fire, explosion, chemical corrosion and serious vibration.

No.
Item
Unit
Data
1
Rated voltage
KV
40.5
2
Rated insulation
       level
1min power frequency 
withstand voltage
Dry test
KV
95
Wet test
80
Lightning impulse withstand voltage(peak value)
185
Rated current
A
2000
Rated short-circuit breaking current
KA
20
25
31.5
Rated short-circuit making current(peak)
KA
50
63
80
Rated operating sequence
O-0.3s-CO-180s-CO
Rated short-time withstand current
KA
20
25
31.5
Rated peak withstand current
KA
50
63
80
Rated short-circuit duration
S
10
Rated control voltage
V
AC220,110;DC220,110
11
Rated short-circuit breaking current break times
Times
20
12
Full-break time
ms
<80
13
Mechanical life
Times
10000
Packing & Delivery 

Strong package, Safety first.

Inside with foam to support the product, put it in carton or wooden box, fixed it on pallet.

As long as possible to keep the products safe until it arriving customer's warehouse.

Clearly marking label outside of package, customers will be easy to identify their goods.
Our Company
20000 M2 of JUCRO Electric company land
1500 M2 of office building
5000 M2 of workshop building
Inside of JUCRO Electric office building


Inside of JUCRO Electric office building
JUCRO Electric office work area
Workshop

Vacuum Interrupter Workshop

Accept customized order.
Design the Vacuum Interrupter for you.

VCB Production Line

VCB Vacuum Circuit Breaker production Line.

VCB Vacuum Circuit Breaker production Line.

VCB Vacuum Circuit Breaker production Line.
Quality Inspection
 Carefully inspection of each product, Quality guaranteed 
 completely data records of entire process , all the product data can be traced. 
Please send your message to us
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.

Professional production line solution provider!

MOBILE WEB
NEWSLETTER

Sign up today for hints, tips and the latest product news - plus exclusive special offers.

Tel:+0086-18131539058

subscription

We don’t do spam and Your mail id is very confidential.