Vacuum Circuit Breaker HVD7 40.5KV 2000A outdoor HV AC VCB from Hubei JUCRO Electric
Vacuum Circuit Breaker HVD7 40.5KV 2000A outdoor HV AC VCB from Hubei JUCRO Electric
Categories | VCB Vacuum Circuit Breaker |
---|---|
Brand | JUCRO |
Model | HVD7-40.5/2000 |
Unit Price | US $ 7076-7674 / piece |
Terms of Payment | L/C, Western Union, MoneyGram, T/T |
Update Time | Dec 11,2024 |
Vacuum Circuit Breaker HVD7 40.5KV 2000A outdoor HV AC VCB from Hubei JUCRO Electric
1. Introduction
HVD7 40.5KV 2000A outdoor HV AC vacuum circuit breaker VCB has many visual advantages like reasonable design, fashionable appearance, high safety and reliability, simple maintenance, long electric life. It is the ideal upgraded products of 35KV outdoor oil circuit breakers.
HVD7 40.5 2000A vacuum circuit breaker is applicable for three-phase power system of AC 50HZ.It is used to make and break the load current ,overload current and short-circuit current.
2. Applicable environment
2.1The ambient temperature should be -30degree~ +40degree(-40degree in the frosty area);
2.2Altitude should not exceed 2000m(over 2000m is plateau type);
2.3The wind pressure should not exceed 700Pa(equal to wind speed 34m/s);
2.4Air pollution degree: 3,that of antifouling type:4;
2.5The installation site should be free from the fire, explosion, chemical corrosion and serious vibration.
No. |
Item |
Unit | Data |
||||
1 |
Rated voltage |
KV | 40.5 |
||||
2 |
Rated insulation level |
1min power frequency withstand voltage |
Dry test | KV | 95 |
||
Wet test | 80 |
||||||
Lightning impulse withstand voltage(peak value) | 185 | ||||||
3 | Rated current | A | 2000 | ||||
4 | Rated short-circuit breaking current | KA | 20 | 25 | 31.5 | ||
5 | Rated short-circuit making current(peak) | KA | 50 | 63 | 80 | ||
6 | Rated operating sequence | O-0.3s-CO-180s-CO | |||||
7 | Rated short-time withstand current | KA | 20 | 25 | 31.5 | ||
8 | Rated peak withstand current | KA | 50 | 63 | 80 | ||
9 | Rated short-circuit duration | S | 4 | ||||
10 | Rated control voltage | V | AC220,110;DC220,110 | ||||
11 | Rated short-circuit breaking current break times | Times | 20 | ||||
12 | Full-break time | ms | <80 | ||||
13 | Mechanical life | Times | 10000 |
Strong package, Safety first.
As long as possible to keep the products safe until it arriving customer's warehouse.
Clearly marking label outside of package, customers will be easy to identify their goods.
Vacuum Interrupter Workshop
Design the Vacuum Interrupter for you.
VCB Production Line
VCB Vacuum Circuit Breaker production Line.
- Tel
- *Title
- *Content
Professional production line solution provider!
Sign up today for hints, tips and the latest product news - plus exclusive special offers.
Tel:+0086-18131539058
We don’t do spam and Your mail id is very confidential.