Transformer Neutral Point BZJ 110V 220V  Series  of Complete Sets of Equipment From Jucro Electric

   BZJ-110/220 series transformer neutral point of complete sets of equipment according to DL/T620-1997 <overvoltage protection and insulation coordination of> Regulations on the 110kV/220kV transformer neutral point of power network uses the gap protection of AC electrical apparatus manufacturing , and in accordance with the China State Grid Corp in 2005 June published <Eighteen grid major anti accident measures to prevent the requirements of grounding grids and overvoltage accidents> in the process if design . Application of 110kV and 220kV effective grounding power network without transformer neutral point grounding overvoltage protection.

    In order to make 110kV transformer neutral point of 220kV substation equipment performance is reliable, convenient installation, commissioning and operation layout is simple and beautiful, the company also introduced the transformer neutral point transformer neutral point rod gap, gap current transformer, isolating switch, lighting arrester, terminal box and a mounting bracket and other electrical equipment in one of the complete sets of equipment.

   The user can choose the transformer neutral point of pure clearance overvoltage protection scheme, also can choose the gap and Arrestor in parallel, collaborative protection scheme. Lighting arrester and the isolation switch according to the need of the project, with flexible group. The actuator isolation switch can be operated manually or electrically. Electrical and mechanical properties of all the products are finished debugging and full set of test before leaving the factory, but also convenient in use and correction.


  

Outline and mounting dimension 

The main parameters of transformer neutral point bar internal number

Nominal clearance Voltage(KV)
Rated system Voltage(KV)
The electrode gap distance Range
The power frequency discharge voltage Range
Insulating electronic The creeppage distance
Transformer Capacity
Air pollution level
Electrode
72.5
110
90-135
50-63
1813
20
Hemispere
72.5
110
90-135
50-63
2248
20
Hemispere
126
220
280-330
100-127
3150
20
Hemispere
126
220
280-330
100-127
3906
20
Hemispere

The main parameters of lighting protection technology

Norminal system 
Voltage(KV)
Type of surge arrester
Arrester rating 
Voltage
DC 1mA reference Voltage greaterthan
8/20 lighting impulse current residual voltage
2ms square wave A
4/big electric
current(KV)
110
YH1.5W-60/144
60
86
144
400
10(65)
110
YH1.5W-72/185
72
105
186
400
10(65)
110
YH1.5W-737/200
73
107
200
400
10(65)
220
YH1.5W-144/320
144
205
320
400
10(65)

The main parameters of GW13

 Item

Unit

Parameters
The product model
GW17-72.5
GW17-126
Rated voltage
KV
72.5
126
 Rated Current
A
630
 Rated peak withstand current
KA
50
 Rated short-time withstand current
KA
20
Rated short duration
S
4
Rated short-circuit withstand voltage
KV
200
200
Rated lighting impluse withstand voltage
KV
385
625

Rated static mechanical load of terminal
Horizontal and vertical
N
1000
1000
 Horizontal
750
750
 vertical force
1000
1000
 Mechnical life
3000
With the motor structure switching time
S
7.5±1(3.75±0.5)
 Weight
KG
120
155

The main parameters of GW8

Item
Unit
Parameters
The product model
GW8-72.5
GW8-126
Rated voltage
KV
72.5
126
Rated Current
A
630
Rated peak withstand current
KA
50
 Rated short-time withstand current
KA
20
Rated short duration
S
4
Rated short-circuit withstand voltage
KV
200
Rated lighting impluse withstand voltage
KV
385
625
Rated static mechanical load of terminal
Horizontal and vertical
N
1000
Horizontal
750
750
 vertical force
1000
Mechnical life
Times
3000
With the motor structure switching time
S
7.5±1(3.75±0.5)
Weight
Kg
90
105
 Packing & Delivery 

Strong package, Safety first.

Inside with foam to support the product, put it in carton or wooden box, fixed it on pallet.

As long as possible to keep the products safe until it arriving customer's warehouse.

Clearly marking label outside of package, customers will be easy to identify their goods.
Our Company
20000 M2 of JUCRO Electric company land

1500 M2 of office building

5000 M2 of workshop building

Vacuum Interrupter Workshop

Accept customized order.
Design the Vacuum Interrupter for you.

VCB Production Line

VCB Vacuum Circuit Breaker production Line.

VCB Production Line

VCB Vacuum Circuit Breaker production line, Engineers routine inspection.
Quality Inspection

Carefully inspection of each product, Quality guaranteed 

 completely data records of entire process , all the product data can be traced. 
Please send your message to us
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.

Professional production line solution provider!

MOBILE WEB
NEWSLETTER

Sign up today for hints, tips and the latest product news - plus exclusive special offers.

Tel:+0086-18131539058

subscription

We don’t do spam and Your mail id is very confidential.