Home / All / Electrical equipment / SF6 Circuit Breaker /

Circuit Breaker HVD8 40.5KV 2000A SF6 from JUCRO Electric

Circuit Breaker HVD8 40.5KV 2000A SF6 from JUCRO Electric

Circuit Breaker HVD8 40.5KV 2000A SF6 from JUCRO Electric
Circuit Breaker HVD8 40.5KV 2000A SF6 from JUCRO ElectricCircuit Breaker HVD8 40.5KV 2000A SF6 from JUCRO ElectricCircuit Breaker HVD8 40.5KV 2000A SF6 from JUCRO ElectricCircuit Breaker HVD8 40.5KV 2000A SF6 from JUCRO Electric
CategoriesSF6 Circuit Breaker
BrandJUCRO
ModelHVD8-40.5/2000
Terms of PaymentL/C, Western Union, MoneyGram, T/T
Update TimeMar 28,2024
Detail Information
HVD8 40.5KV 2000A SF6 Circuit Breaker from JUCRO Electric
Detailed Image
1.  Product description
HVD8 /LW8-40.5 type outdoor high-pressure sulfur hexafluoride circuit breaker is three-pole ac 50 hz, outdoor high voltage switch equipment, applicable to 40.5 kV power transmission and distribution system control and protection, can also be used to contact circuit breaker and movable capacitor group.
Standard: IEC 62271-100.
Certification: ISO9001-2015
Operation: Energy-storage Type
Installation: Fixed
Arc-extinguishing Medium: SF6
Speed: Normal Type Circuit Breaker
HS Code: 85353000

a.        The circuit breaker is outdoor small ceramic column structure, which equipped with CT14 spring operation mechanism; mechanism and main part connected with simple installation. It has features of convenient adjustment, reliable operation, suitable for frequent operation; mechanism service life more than 3000 times;

b.       Adopt air-compression arc-extinguishing structure, with strong breaking capacity, 40kA total breaking times up to 12, which is the highest in China:

c.        Reliable sealing performance. Adopt import seal; dynamic seal adopts "V" type sealing ring with spring pressure compensation structure; the transformer secondary wiring board matched by cooperative enterprises, to ensure the annual leakage rate less than 1%,

d.       Inner current transformer adopts micro crystallizing alloy high magnetic materials, with accurate class up to grade 0. 2 or grade 0.2S. According to users' needs, it can be matched with 12 transformers, to meet the load line of 50 km without restrike.


2.  Main technical specification:
Item
Unit
Date
Rated voltage
KV
40.5
Rated insulation
       level
Lightning impulse withstand voltage(peak value)
KV
185
1min power frequency 
withstand voltage
KV
95
Rated current
A
2000
Mechanical life time
time
3000
Rated air pressure of SF6 (psig at 20)
Mpa
0.05
Alarm pressure/Min function pressure (psig at 20)
Mpa
0.47/0.45

Rated short-circuit breaking current

KA
40

Rated short circuit making current (peak value)

100
Rated short time withstand current (thermal stability current)
40
Rated peak withstand current (dynamic stability current)
KA
100
Rated out of step breaking current
KA
10
Rated breaking times under short circuit breaking current
time
12
Rated short circuit duration
S
4
Closing time (under rated operation voltage)
S
≤0.1
Opening time (under rated operation voltage)
S
≤0.06
Rated operating sequence
O-0.3s-CO-180s-CO

Rated making single capacitor bank current

A
400

Annual leakage rate

%
≤1
SF6 water content(V/V)
≤150*10-6
Rated operation voltage of matched CT14 spring operation mechanism 
Closing and opening coil voltage 
V
AC: 220 380  DC: 18 110 220
Energy storage motor voltage
V
AC: 220 380  DC: 110 220
Weight of SF6 gas
kg
8
Weight of circuit breaker (including operation mechanism)
kg
1400
Item
Unit
Data
Technical parameter

Moving contact travel

mm
95±2
Measure moving contact travel

Opening distance between contacts

mm
60±1.5

Measure distance between moving and fixed contact

Pole-to-pole closing synchronous
ms
≤3
Measure pole distance difference between moving and fixed contact
Pole-to-pole opening synchronous
ms
≤2

Measure pole distance difference between moving and fixed contact

Main circuit resistance
≤120

Measure DC voltage reduction

Closing speed

m/s
3.2±0.2

Rated air pressure, measuring method

Opening speed

m/s
3.4±0.2

Rated air pressure, measuring method

Closing buffer distance
mm
9.5-11

Under closing state

Spacer of closing buffer
mm
1-2

Under closing state

Partial 48.6kV
Pc
20
Measure by partial measuring device under rated air pressure; apply voltage 486kv on the two out-line ends of the circuit breaker for 1 min, then reduce the voltage to 28V to measure
Disharge 28kV
Pc
10

Strong package, Safety first.

Inside with foam to support the product, put it in carton or wooden box, fixed it on pallet.

As long as possible to keep the products safe until it arriving customer's warehouse.

Clearly marking label outside of package, customers will be easy to identify their goods.
20000 M2 of JUCRO Electric company land

1500 M2 of office building

5000 M2 of workshop building

Vacuum Interrupter Workshop

Accept customized order.
Design the Vacuum Interrupter for you.

VCB Production Line

VCB Vacuum Circuit Breaker production Line.

VCB Production Line

VCB Vacuum Circuit Breaker production line, Engineers routine inspection.

 Carefully inspection of each product, Quality guaranteed 

 completely data records of entire process , all the product data can be traced. 
Please send your message to us
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.

Professional production line solution provider!

MOBILE WEB
NEWSLETTER

Sign up today for hints, tips and the latest product news - plus exclusive special offers.

Tel:+0086-18131539058

subscription

We don’t do spam and Your mail id is very confidential.