Home / All / Electrical equipment / VCB Vacuum Circuit Breaker / 12KV Vacuum Circuit Breaker Draw out type VED 1250A 25KA with copper parts 210mm phase distance replace of VD4

12KV Vacuum Circuit Breaker Draw out type VED 1250A 25KA with copper parts 210mm phase distance replace of VD4

12KV Vacuum Circuit Breaker Draw out type VED 1250A 25KA  with copper parts 210mm phase distance replace of VD4
12KV Vacuum Circuit Breaker Draw out type VED 1250A 25KA  with copper parts 210mm phase distance replace of VD412KV Vacuum Circuit Breaker Draw out type VED 1250A 25KA  with copper parts 210mm phase distance replace of VD412KV Vacuum Circuit Breaker Draw out type VED 1250A 25KA  with copper parts 210mm phase distance replace of VD412KV Vacuum Circuit Breaker Draw out type VED 1250A 25KA  with copper parts 210mm phase distance replace of VD4
  • Price
  • US $1193-1420
  • Model
  • VED 12KV 1250A 25KA
  • Unit Price
  • Order QuantityUnit PriceDelivery period
    1 - 10US $1420.00/piece15 day
    11 - 100US $1193.00/piece15 day
  • Quantity
Detail Information

    Draw out type VED-12KV 1250A 25KA VCB vacuum circuit breaker with copper parts 210mm phase distance replace of VD4

    Vacuum Circuit Breaker accept customized order according to technical drawing or samples.
    VED-12 series indoor high voltage vacuum circuit breaker is suitable for 12kV air-insulated indoor switchgear, used as protection and control unit of power equipment of industrial & mining enterprise. Due to the super excellence, it is especially suitable for locations where requires the frequent operation under rated working current or multiple breaking under short circuit breaking current. The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also draw-out type equipped with a special propelling mechanism.
    VED-12 has two main types. One is Draw-out type. Model No. is VED-12D. The other is Fixed type. Model No. is VED-12F.

    Service conditions 
    1 Environment temperature:-15℃~+40℃;
    2 Environment humidity: Daily average relative humidity:≤95%, monthly average relative humidity:≤90%; Daily average saturated vapor pressure:≤2.2×10-3Mpa,monthly average saturated vapor pressure:≤1.8×10-3Mpa;
    3 Altitude: Not exceed 1000m;
    4 Earthquake intensity: Not exceed&degree;
    5 Service location: No water, flammable or explosive matter, chemical corrosive gas or drastic vibration. 
    Parameter
    1
    Rated voltage
    KV
    12
    2
    Rate voltage
    Hz
    50
    3
    Rated lightning impulse withstand voltage(1min)
    KV
    75
    4
    Rated short-time power frequency withstand voltage (1min)
    KV
    42
    5
    Rated short-circuit breaking current
    KA
    20
    25
    31.5
    40
    6
    Rated current
    A
    630,1000,1250
    630,1000,1250,1600
    1250,1600,2000,2500
    1600,2000,2500,3150
    7
    Rated peak withstand current
    KA
    50
    63
    80
    100
    8
    Rated shorted-time withstand current
    KA
    20
    25
    31.5
    40
    9
    Rated shorted-time making current(peak)
    KA
    50
    63
    80
    100
    10
    Power frequency withstand voltage of secondary circuit(1min)
    V
    2000
    11
    Rated operation sequence

    Off-0.3s-On&Off-180s- On& Off
    Off -180s- On& Off -180s- On& Off*
    12
    Rated breaking current of capacitor bank
    A
    630/400(40kA 800/400)
    13
    Opening time(rated voltage)
    ms
    30~70
    14
    Closing time(rated voltage)
    ms
    30~70
    Packing & Delivery 

    Strong package, Safety first.

    Inside with foam to support the product, put it in carton or wooden box, fixed it on pallet.

    As long as possible to keep the products safe until it arriving customer's warehouse.

    Clearly marking label outside of package, customers will be easy to identify their goods.
    Our Company
    20000 M2 of JUCRO Electric company land
    1500 M2 of office building
    5000 M2 of workshop building
    Inside of JUCRO Electric office building
    Inside of JUCRO Electric office building
    JUCRO Electric office work area
    Workshop

    Vacuum Interrupter Workshop

    Accept customized order.
    Design the Vacuum Interrupter for you.

    VCB Production Line

    VCB Vacuum Circuit Breaker production Line.

    VCB Vacuum Circuit Breaker production Line.

    VCB Vacuum Circuit Breaker production Line.
    Quality Inspection
     Carefully inspection of each product, Quality guaranteed 
     completely data records of entire process , all the product data can be traced. 
    Please send your message to us
    *Email
    Phone
    *Title
    *Content
    Upload
    • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.

    Professional production line solution provider!

    MOBILE WEB
    NEWSLETTER

    Sign up today for hints, tips and the latest product news - plus exclusive special offers.

    Tel:+0086-18131539058

    subscription

    We don’t do spam and Your mail id is very confidential.